Site Maps: containers and racks

How to use site maps in EMCD Monitoring: set up containers and racks, place devices and quickly find an overheated or switched-off miner.

A site map shows where each device physically stands and what state it is in. It makes an overheated or switched-off miner quick to find on the farm.

What's on the map

At the top are site tabs and a summary: Placed, Free slots, Unplaced, Avg. Hashrate, Power.

Below are containers. A container holds racks with a grid of shelves and slots. Each cell is one device; its colour shows a metric.

The Metric switch changes what the colour shows:

  • State — Normal · Risk · Failure · Offline;

  • Hashrate;

  • Power;

  • Temperature.

The State filter leaves only devices with the chosen status on the map.

How to set up a container

  1. Open Site Maps and pick a site.

  2. Click Add container (on an empty site — Set up containers).

  3. Enter a name.

  4. Choose a network — devices from it go to this container. The network is optional. The list only shows networks not tied to another container.

  5. Save.

A container can have up to 16 racks, each with 1 to 64 shelves and slots. Drag racks to reorder them. Only an administrator can delete a rack that holds devices.

How to place devices

After a scan, new devices from the container's network land in Unplaced. Open the container and:

  • drag a device to its slot;

  • or click Auto-fill rack — devices are placed in IP order: shelves bottom to top, slots left to right. Devices in Waiting are not placed.

To free a slot, select the device and click Unplace.

Next step: Notifications.