Skip to main content

Devices and metrics

How to work with the device list in EMCD Monitoring: columns, filters and sorting, the device card, rated values and bulk actions on ASICs.

Devices lists every ASIC miner in your organization.

Device list

For each device the table shows model, name, IP address, site, container, status, pool, worker, case serial, hashrate, power, temperature, ping, uptime, work mode and client. The table scrolls sideways.

At the bottom are status counters: Failure, Risk, Normal, Off. They follow the filters above the table.

Switch the period — 1 hour, 24 hours or 7 days — above the table.

Choosing columns

Open the column settings and tick the columns you need. Up to 16 columns can be on at once.

Name

The name comes from the miner itself if the firmware reports one. You can set your own name in the device card. Polling the miner never overwrites your own name. No name — the cell shows "—".

Pool and worker

  • Pool — the address the device is mining on right now, with a green dot. If the firmware moved from the first address to a backup, the address is orange with "switched" below it.

  • Worker — the worker for that address. If other addresses use a different worker, you'll see a grey "+1" or more next to it.

Click a Pool cell to open the Stratums list, marked "firmware switches in round-robin". Each address shows its worker and the status reported by the firmware:

  • Active — the device is mining here;

  • Responding — the address is reachable;

  • Not responding — the address is down.

If an address is down, a hint below shows which address the device is mining on now. Monitoring only shows these statuses — it does not check or switch addresses itself. Edit stratums opens the pool setup for this device.

Case serial

This is the number from the sticker on the case. You need it when the control board was replaced and the board serial changed.

  1. Click the Case Serial cell. An empty cell shows + Add.

  2. Type the number or scan the sticker with a barcode scanner.

  3. Press Enter — the number is saved and input moves to the next row.

This way you can scan a whole row of devices one after another. Esc cancels. The number is up to 64 characters and must not repeat on another device. Polling the miner never overwrites it.

Filters and sorting

Above the table are filters by Site, Container, Status and Pool, plus a No client checkbox. In the Pool filter you can pick one or more pool addresses. The filters window adds: working / offline, device model, mode, client.

Counters and the containers table on Home open this page with the right filter already applied.

Click a column header to sort by status, hashrate, power, temperature, ping or uptime.

Device card

Click a row to open the device card.

The header shows model, Name, serial number, site, worker and client.

  • Name — click the pencil, enter your own name and save.

  • Serial number — the case serial, edited with the pencil. The serial read from the board is shown next to it in grey.

Norm

In Key metrics, under hashrate, power and temperature, there is a Norm line. By default the norm matches the model, for example "Norm: model default, 3.07 kW".

The norm is what Risk and Failure, notifications and metric colours in the card are measured against. Set your own norm if the device runs underclocked or never reached its rated values.

  1. Click the pencil on the Norm line.

  2. Enter the value and click Save.

  3. To go back to the model value, click Reset below the field.

The Metrics tab has charts:

  • Hashrate — computing power. Units (TH/s, GH/s, MH/s) are picked to fit the value.

  • Power — consumption, W.

  • Fan speed — RPM.

  • Board temperature — °C per board.

  • Voltage — V.

  • Uptime — continuous running time.

  • Chips — working and failed.

  • Ping — network latency to the device, ms.

  • Reboots — reboots during the period.

  • State — Working / Error / Offline.

  • Mode — Sleep, Low, Normal, High, Turbo. Available modes depend on the model and firmware.

The Pools tab has its own article.

Device actions

Tick one or more devices. An action panel appears in the bottom right:

  • Assign client / Change client / Unlink client;

  • Edit — change the work mode and the norm;

  • Configure pool — write new pool addresses to all selected devices;

  • Reboot;

  • Set to waiting — a waiting device doesn't count toward your subscription limit;

  • Remove from Monitoring.

On the Waiting tab you get Activate and delete instead.

Norm for several devices

  1. Tick the devices and click Edit.

  2. In the norm block, fill in the fields you need: Hashrate, TH/s, Power, kW, Temperature, °C.

  3. Click Save.

Empty fields are not changed. Filled values are applied to every selected device. If you selected different models, the window warns you — you can still save. Reset to Model Default removes the own norm from all selected devices.

Pool for several devices

  1. Tick the devices and click Configure pool.

  2. Enter up to three pool addresses and passwords.

  3. Click Continue.

Each device keeps its own worker. If some devices have no worker, the window warns you before saving — the pool won't be written to them. Set their worker in the device card, on the Pools tab.

After saving, a notice appears in the bottom right: "Pool configured on N devices · Previous pools saved", with the time and who did it.

Restore previous pools writes the addresses those devices had before the change. A notification "Previous pools restored: X of Y" shows how many devices were restored. The button is available while the notice is open.

Both the change and the restore appear in the Activity Feed on Home and in Logs.

Which of these work depends on the employee's role and the miner's firmware — see "Supported hardware".

How to add devices

Devices are added by the agent's autoscan (see "Sites, networks and autoscan"). Add devices opens the agent installation. If the agent is already installed, check the site networks — the device's address must fall into one of them.

Important: the owner and employees make any remote changes to equipment settings — including bulk pool changes and norm changes — and reboots at their own risk.

Use of EMCD Monitoring is governed by the Product Terms Monitoring.

Did this answer your question?