Skip to main content

Home: system status

What the Home page in EMCD Monitoring shows: device summary, hashrate chart, containers and activity feed, refreshed about every 30 seconds.

Home shows what is happening on your farm right now: how many devices are working, where something failed and what was changed recently. The page refreshes itself, roughly every 30 seconds, so you can keep it open on a screen in the server room.

Header and filters

At the top are the System status heading and the Fullscreen button. It hides the side menu so the data takes the full width. Exit Fullscreen brings the menu back.

Below the heading are three filters: Site, Container and Client. They apply to the whole page — summary, chart, containers and feed.

Summary

Four cards with numbers.

  • Devices — Active and Waiting. "Active" means all monitored devices, including those that are off. Below: Failure, Risk, Normal, Off.

  • Energy — Energy (24h) in large type. Below: Now (current power) and Total (rated power of all devices).

    Energy figures are for reference only. If the firmware doesn't report power, it is estimated from the model's rated power. Don't use these figures for settlements with your energy supplier, the regulator or official reporting.

  • Hashrate — shown separately for each algorithm, in its own units. SHA-256 and Scrypt are never added together. The first algorithm shows the change over 24h: a green arrow up or a red arrow down.

  • Temperature — Avg. Temp and Overheating, devices: how many devices run hotter than their model's norm.

Every counter is clickable. Click, for example, Failure or Overheating, devices to open Devices with only those devices.

Chart

One chart with tabs:

  • Working, units — how many devices were online and mining. Opens by default.

  • Hashrate — pick the Algorithm on the right.

  • Temperature — average across the selected devices.

  • Power — energy used per hour, MWh.

Period — 1 hour, 24 hours, 7 days or Custom range. For a custom range, pick dates in the calendar and click Apply. The point step is chosen automatically: 5 minutes for an hour, 1 hour for up to a month, 1 day for longer.

Above the chart are three numbers: the current value, the minimum and the maximum for the period. They depend on the tab — for example, Power shows Consumed for period, Peak power and Total.

Hover over the chart to see the time, the value and a breakdown by container.

Containers

The containers table shows site, Active, Power, average temperature and Issues — failures, warnings and overheating with the number of devices.

  • With issues — only containers where something is wrong. Opens by default.

  • All — every container.

Click a row to open Devices for that container. To site map opens the rack layout.

Activity Feed

On the right are the latest farm events.

  • Alerts — failures grouped by container and type. For example: "+17 no hashrate in 14 minutes" with "total no hashrate 50 · alert active for 12 minutes" below. Types: no hashrate, offline, overheat, power spike.

  • Actions — what employees and schedules did: reboot, pool change, mode change, client change, moving to and from waiting, scheduled runs. Below: who did it and how many succeeded. Changes made on the device itself, outside Monitoring, are marked "detected by metrics".

All events opens Notifications.

No devices yet

Instead of the summary you'll see a prompt to download the agent. It finds devices on your site's networks by itself — see "Installing Miner Agent".

Use of EMCD Monitoring is governed by the Product Terms Monitoring.