Skip to main content

Sites, networks and autoscan

How to create a site in EMCD Monitoring, assign an operator and technicians, add site networks for autoscan and set up schedules.

A site is a farm or part of one. The agent, devices and employees are tied to a site.

How to create a site

  1. Open Sites.

  2. Click Add site.

  3. Enter a name.

  4. Assign the responsible operator.

  5. Assign technicians if needed.

  6. Click Add.

By assigning employees to a site, you give them the right to manage its equipment.

To edit or archive a site, use the ⋯ menu in the list. Archive a site that no longer runs but whose history you want to keep.

Site networks and autoscan

You no longer search for miners by hand. You list the site's networks, and the agent scans them and adds the devices it finds.

  1. Open Site Maps and click Site networks.

  2. Paste the addresses. A range (10.0.1.1-10.0.1.254), a subnet (192.168.0.0/24) or a single address all work. One network per line.

  3. If the site has containers, choose which container devices from this network go to.

  4. Click Save and scan (Save for later changes).

After you save:

  • a scan starts right away;

  • after that the agent repeats it automatically 5 minutes after the previous pass ends — this picks up new devices and devices whose IP changed;

  • found devices appear in Devices straight away. Serial numbers no longer need to be confirmed by hand.

Limits: up to 192 networks and 20,480 addresses per site, across all networks.

If there are more devices than your subscription allows, the extra ones get the Waiting status. They don't count toward the limit until you activate them.

Important: deleting a network removes its devices from monitoring. Only an administrator can delete networks.

Schedules

A schedule runs an action on devices at a set time. For example, it stops mining during peak electricity hours and starts it again at night.

  1. Open Sites and click All rules.

  2. Click Create rule.

  3. Choose an action: Reboot devices, Turn on devices or Set to Waiting. Add action adds another action to the rule.

  4. Choose devices, time, days of the week and time zone.

  5. Save.

In a schedule, "Set to Waiting" stops mining on the device. It is not the subscription "Waiting" status: the device stays in monitoring and counts toward the limit.

Rule menu: Edit, Pause / Resume, Run now, Delete. The Trigger history tab shows when the rule ran and with what result.

Use of EMCD Monitoring is governed by the Product Terms Monitoring.

Did this answer your question?